Worldwide UPS Shippng Options (1-5 businss days) -- US shipping starts at $7.50

Omron S8VS-12024B 24 VDC power supply with current voltage display 120W 5A
Omron S8VS-12024B 24 VDC power supply with current voltage display 120W 5A
Omron S8VS-12024B 24 VDC power supply with current voltage display 120W 5A
Omron S8VS-12024B 24 VDC power supply with current voltage display 120W 5A
Omron S8VS-12024B 24 VDC power supply with current voltage display 120W 5A
  • Load image into Gallery viewer, Omron S8VS-12024B 24 VDC power supply with current voltage display 120W 5A
  • Load image into Gallery viewer, Omron S8VS-12024B 24 VDC power supply with current voltage display 120W 5A
  • Load image into Gallery viewer, Omron S8VS-12024B 24 VDC power supply with current voltage display 120W 5A
  • Load image into Gallery viewer, Omron S8VS-12024B 24 VDC power supply with current voltage display 120W 5A
  • Load image into Gallery viewer, Omron S8VS-12024B 24 VDC power supply with current voltage display 120W 5A

Omron S8VS-12024B 24 VDC power supply with current voltage display 120W 5A

Vendor
Omron
Regular price
$125.00 USD
Sale price
$125.00 USD
Regular price
Sold out
Unit price
per 
Shipping calculated at checkout.
We have 6 in stock.

DC power supply made by Omron.  This is a new surplus item in its original box.

PN:
S8VS-12024B



Covered type, Natural air-cooling, Input: 80 to 370 VDC 100 to 240 VAC, Power ratings: 120 W, Output: 24 VDC

Power rating 120 W
Rated input voltage 100 to 240 VAC
Output voltage 24 VDC
Heat radiation Natural air-cooling
Construction Covered type
Terminal type Screw terminal
Mounting type DIN Rail mounting type


Power rating 120 W
Efficiency 83% TYP.(At 100 VAC input)
85% TYP.(At 200 VAC input)
Rated input voltage 100 to 240 VAC
Allowable input voltage variable range 85 to 264 VAC
80 to 370 VDC
Note at DC input The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).
Frequency 50/60 Hz(47 to 63 Hz Single-phase)
Rated input curren 1.5A TYP. (At 100 VAC input)
0.72A TYP. (At 200 VAC input)
Power factor 0.9 Min.
Leakage current 0.5 mA Max. (At 100 VAC input)
1.0 mA Max. (At 200 VAC input)
Inrush current 14 A TYP. (At 100 VAC input (For cold start at 25 CEL))
28 A TYP. (At 200 VAC input (For cold start at 25 CEL))
Output voltage 24 VDC
Output voltage variable range -10 to +15 % (With V. ADJ)
(The output voltage may increase beyond the allowable voltage range (up to +15% of the rated voltage) depending on the operation of the output voltage adjuster (V.ADJ). When adjusting the output voltage, check the output voltage of the Power Supply and be sure that the load is not damaged.)
Ripple 2%(p-p) Max. (Under the rated I/O conditions.)
130mV Max. (Under the rated I/O conditions.)
Static input variation influence 0.5% Max. At 85 to 264 VAC input, 100% load
Static load variation influence 1.5% Max. At rated input, 0 to 100% load
Ambient temperature variation influence 0.05 %/CEL Max.
Rated output current 5 A
Start up time 650 ms TYP. (100 VAC input)
520 ms TYP. (200 VAC input)
Hold time 56ms TYP. (100 VAC input)
56ms TYP. (200 VAC input)
Overload protection 105% to 160% of the rated output current
Inverted L voltage drop, Automatic reset
Overvoltage protection Operated at 130% Min. of the rated output voltage, Shut-off
Resetting: Reset the power by turning it back (OFF time: at least 3 min)
Overheat protection No
Output voltage indication Yes (Resolution: 0.1V / Accuracy: +/- 2% (percentage of output voltage value) +/- 1 digit Max.)
Output current indication Yes (Resolution: 0.1A / Accuracy: +/- 5% F.S. (percentage of rated output current value) +/- 1 digit Max.)
Peak-hold current indication Yes (Resolution: 0.1A / Accuracy: +/- 5% F.S. (percentage of rated output current value) +/- 1 digit Max. / Minimum_detectable_signal_width: 10 ms (20 ms Max.))
Maintenance forecast monitor output No
Total run time monitor indication Yes (Resolution: 1 kh / Setting range: 1 to 150 kh)
Total run time monitor output Yes (open collector output), 30 VDC Max., 50 mA Max., Sinking (NPN)
Undervoltage alarm indication Yes (Resolution: 0.1 V / Setting range: 18.5 to 27.5 V)
Undervoltage alarm output Yes (open collector output), 30 VDC Max., 50 mA Max., Sinking (NPN)
Power failure alarm output No
Parallel operation No (However, backup operation is possible; external diodes required.)
N+1 redundant system -
Series operation Yes (Up to 2 Power Supplies with external diode)
Remote sensing function No
Dielectric strength Between all inputs and all outputs/alarm outputs: 3 kVAC for 1 min (Detection current: 20 mA)
Between all inputs and PE terminals: 2 kVAC for 1 min (Detection current: 20 mA)
Between all outputs/alarm outputs and all PE terminals: 1 kVAC for 1 min (Detection current: 20 mA)
Between all outputs and all alarm outputs: 500 VAC for 1 min (Detection current: 20 mA)
Insulation resistance Between all outputs/alarm outputs and all inputs/PE terminals: 100 MOhm Min. (at 500 VDC)
Vibration resistance 10 to 55 Hz, 0.375 mm single amplitude in each 3 directions for 2 hours
Shock resistance 150 m/s**2, in each 6 directions 3 times
Output indicator Yes (color: green)
Heat radiation Natural air-cooling
Construction Covered type
Terminal type Screw terminal
Mounting type DIN Rail mounting type
Weight (Main) Approx. 550 g