Worldwide UPS Shippng Options (1-5 businss days) -- US shipping starts at $7.50

IFM O1D100 Laser Distance Sensor Analog Output IO-Link
IFM O1D100 Laser Distance Sensor Analog Output IO-Link
IFM O1D100 Laser Distance Sensor Analog Output IO-Link
IFM O1D100 Laser Distance Sensor Analog Output IO-Link
IFM O1D100 Laser Distance Sensor Analog Output IO-Link
  • Load image into Gallery viewer, IFM O1D100 Laser Distance Sensor Analog Output IO-Link
  • Load image into Gallery viewer, IFM O1D100 Laser Distance Sensor Analog Output IO-Link
  • Load image into Gallery viewer, IFM O1D100 Laser Distance Sensor Analog Output IO-Link
  • Load image into Gallery viewer, IFM O1D100 Laser Distance Sensor Analog Output IO-Link
  • Load image into Gallery viewer, IFM O1D100 Laser Distance Sensor Analog Output IO-Link

IFM O1D100 Laser Distance Sensor Analog Output IO-Link

Vendor
IFM
Regular price
$340.00 USD
Sale price
$340.00 USD
Regular price
Sold out
Unit price
per 
Shipping calculated at checkout.
We have 1 in stock.

Manufacturer:  IFM
Part No: O1D00 or 01D100
Condition:  New surplus item, comes in original box.
Description: IO link version of the O1D100.


Product characteristics
Measuring range [m] 0.2...10; (white paper 200 x 200 mm 90% remission)
Communication interface IO-Link
Laser protection class 2
Housing rectangular
Dimensions [mm] 59 x 42 x 52
Electrical data
Operating voltage [V] 18...30 DC; (operating voltage "supply class 2" according to cULus)
Current consumption [mA] < 150
Protection class III
Reverse polarity protection yes
Typ. lifetime [h] 50000
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1
Outputs
Total number of outputs 2
Electrical design PNP
Number of digital outputs 2
Output function normally open / normally closed; (parameterisable)
Max. current load per output [mA] 200
Number of analogue outputs 1
Analogue current output [mA] 4...20; (IEC 61131-2)
Max. load [Ω] 250
Analogue voltage output [V] 0...10; (IEC 61131-2)
Min. load resistance [Ω] 5000
Short-circuit protection yes
Type of short-circuit protection pulsed
Overload protection yes
Detection zone
Max. light spot width [mm] 15
Max. light spot height [mm] 15
Light spot dimensions refer to 10 m
Background suppression [m] 0...19
Measuring/setting range
Measuring range [m] 0.2...10; (white paper 200 x 200 mm 90% remission)
Sampling rate [Hz] 1...50
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
Profiles Smart Sensor: Sensor Identification; Binary Data Channel; Process Value; Sensor Diagnosis
SIO mode yes
Required master port type A
Process data analogue 2
Process data binary 3
Min. process cycle time [ms] 6